您好,歡迎來到易龍商務(wù)網(wǎng)!
全國咨詢熱線:13706307046

稱多移動式混流泵安裝性價比出眾,金石泵業(yè)

【廣告】

發(fā)布時間:2020-12-16 07:40  






混流泵


 2、水泵起動后有一股水就不出水了

 After starting ,

 the pump only send one stream water then no water runs out

 1、吸入的水中有過多氣泡

 2、吸水管中窩存空氣

 3、吸水管或連接處墊料不嚴密有進氣現(xiàn)象

 4、底閥或葉輪有水草雜物填塞

 1.There are too many bubbles in the

 indrawn water

 2.There is air in the suction pipes

 3.The paddings in connected parts are

 imprecision and produces leaking phenomenon

 4.There are waterweeds and sundries

 filled in the bottom valve or impeller

 1、檢查進水管末端是否在水平面以下一米左右

 2、排除空氣

 3、高速墊料,填塞縫隙擰緊螺栓

 4、消除水草雜物

 1.Check the end

 of water inlet pipe if it is under the water surface at one meter

 2. Remove the

 air

 3.Add padding to

 fill the gaps and then tighten the bolts

 4.Clear the

 waterweeds and sundries.


按用途分類輸送泵、循環(huán)泵、消防泵、試壓泵、排污泵、計量泵、衛(wèi)生泵、加藥泵、糊化泵、輸液泵、消泡泵、流程泵、輸油泵、給水泵、排水泵、疏水泵、挖泥泵、噴灌泵、增壓泵、高壓泵、保溫泵、高溫泵、低溫泵、冷凝泵、熱網(wǎng)泵、冷卻泵、暖通泵、深井泵、抽氣泵、血液泵、抽料泵、除硫泵、剪切泵、研磨泵、燃油泵、吸魚泵、浴缸泵、源熱泵、過濾泵、增氧泵、洗發(fā)泵、注射泵、充氣泵、燃氣泵、美工泵、加臭泵、切碎泵

電動機過熱

原因有四。一是電源方面的原因:電壓偏高或偏低,在特定負載下,若電壓變動范圍應在額定值的 10%至-5%之外會造成電動機過熱;電源三相電壓不對稱,電源三相電電壓相間不平衡度超過5%,會引繞組過熱;缺相運行,經(jīng)驗表明農(nóng)用電動機被燒毀85%以上是由于缺相運行造成的,應對電動機安裝缺相保護裝置。二是水泵方面的原因:選用動力不配套,小馬拉大車,電動機長時間過載運行,使電動機溫度過高;啟動過于頻繁、定額為短時或斷續(xù)工作制的電動機連續(xù)工作。建議優(yōu)先考慮購買充水式潛水電泵,并且看清牌號和產(chǎn)品質(zhì)量合格證。應限制啟動次數(shù),正確選用熱保護,按電動機上標定的定額使用。三是電動機身的原因:接法錯誤,將△形誤接成Y形,使電動機的溫度迅速升高;定子繞組有相間短路、匝間短路或局部接地,輕時電動機局部過熱,嚴重時絕緣燒壞;鼠籠轉(zhuǎn)子斷條或存在缺陷,電動機運行1至2小時,鐵芯溫度迅速上升;通風系統(tǒng)發(fā)生故障,應檢查風扇是否損壞,旋轉(zhuǎn)方向是否正確,通風孔道是否堵塞;